18

DXC910 OPERATIONS MANUAL

2007/05/17

CALLER ID

Each subscriber in the system has 12 alphanumeric characters for identification. This ID is available for

display on the called station (DAD104) and for Event Logging (DNA100). Default is all spaces.

PROGRAMMING

The following commands are used for this feature:
SCID

Set Caller ID

LCN

List Call Number

Example: Set Caller ID for call number 14 to “Lobby”.
>SCID

cr

Call Number <10-99/*> : 14

cr

Caller ID <alphanumeric> : Lobby

cr

>LCN

cr

Call Number <10-99/*> : 14

cr

Line Call In Priority
Equ. Number Caller ID Type QUE Alarm Call Annunciator Printer Video
==== ========= ========== ==== ==== ===== ==== =========== ======= =====
$04 14 Lobby ICM RING 1 5 ... ... ...
>

DEVICE TYPES

The device type defines the operation of intercom stations.

Type0 = Undefined
Type1 = SUB (DC shift substation)
Type2 = ICM (Master station or substation using speed-dial)
Type3 = PTT (Telephone line)
Type4 = TIE (Intersystem Tie-line)

PROGRAMMING

The following commands are used for this feature.
SDT

Set Device Type

LCN

List Call Number

>SDT

cr

Call Number <10-99/*> : 11-14

cr

Device Type(0=U 1=SUB 2=ICM 3=PTT 4=TIE)<0..4> : 1

cr