MODEL OF GENERATOR

HR-20, HR-25, and HR-30

Oil Cooler

Dimensions (Core)

7.5”D x 18.9” W x 32.3”L

Fan

Voltage

Amperage

16 Inch Pusher

12 Volts DC

22 Amps

Filter

10 Micron

Hydraulic Oil

(recommended)

(alternate)

Maximum Viscosity


Op. Temp. range

(deg. F.)

Dexron III

ISO Approved Hydraulic Fluid

4600 SUS (1000mm2/S)

60 SUS (10mm2/S)

-13° F to 195° F

Hoses

Motor Inlet

All Others

SAE

6000 psi, SAE

1250 psi, SAE

Fittings

SAE

Dry Weight

(without pump)

675 lbs

Dimension of Tray Asm.

40” L x 19” W x 22” H

(Including Reservoir)

Ambient Operating

Temperature Range

0

°F to 120°F

Table 1 (cont.)


Note 1:
The HR-20, HR-25 and HR-30 systems can provide 84 amps, 105 amps and 125
amps respectively on each of their two 120 volt circuits as long as the circuit-to-circuit
imbalance does not exceed the maximum recommended value of 20% (See page 21 for
more information and warnings).

Note 2: The recommended PTO ratio is 1.29 : 1 (129%).
The recommended engine idle speed with this PTO is 750 RPM.
This will result in a 968 RPM pump drive input, thereby insuring 5KW
of available power at engine idle. If full output is required at idle speed, then a higher PTO
ratio must be chosen to create 1200 RPM pump drive at idle speed; however care must
be taken to prevent higher engine speeds from creating a pump speed that exceeds the
pump’s maximum speed.