Maintenance instructions – Smart Power Systems HR-30 User Manual

Page 34

Advertising
background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 33 of 50

Message advising the
oil is cold (less than
40

°F)

Measured oil
temperature in
degrees fahrenheit

Example of Command & Control Center

when operating with cold hydraulic fluid

Figure 24



Operating Modes when the system START button is activated (or when the system is in
“autostart”):

• When the meter displays hydraulic oil temperatures below 20°F, the hydraulic

system will bypass the generator motor and the generator will not produce
power. This mode warms the hydraulic oil.


• When the meter displays hydraulic oil temperatures between 20° and 40°F, the

generator rotor will turn at a reduced RPM and the generator will not produce
power. This warms the hydraulic oil to 40

°F.

• When the meter displays hydraulic oil temperatures that exceed 40°F, the

system will then commence full power generating operations.

Maintenance Instructions


WARNING:


Do not perform maintenance while system is running.

1.

Perform regular, periodic checks to verify:

a. The cooler, the cooler fan and generator vents are not plugged by debris.
b. There are no fluid leaks within the framework of the generator, along the hoses,

or at the pump.

c. The hoses are not cut, chaffed, bulged or kinked.
d. That no electrical connections are loose.
e. That the hydraulic fluid level in the reservoir is between ½ to ¾ full in the sight

gage and the hydraulic fluid is clean and bright red in color.

f. That the bolts mounting the pump to the PTO are not loose.