Smart Power Systems Liberator Series User Manual

Page 11

Advertising
background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 10 of 54

MODEL OF

GENERATOR

LI-15

LI-20

LI-25

Oil Cooler

Dimensions (Core)

7.5”D x 18.9” W x 27.25”L

7.5”D x 18.9” W x 32.3”L

7.5”D x 18.9” W x 32.3”L

Fan

Voltage

Amperage

12 Inch Pusher

12 Volts DC

22 Amps

16 Inch Pusher

12 Volts DC

22 Amps

16 Inch Pusher

12 Volts DC

22 Amps

Filter

10 Micron

10 Micron

10 Micron

Hydraulic Oil

(recommended)

(alternate)


Maximum Viscosity

Minimum Viscosity

Op. Temp. range

(deg. F.)

Dexron III

ISO Approved Hydraulic

Fluid

4650 SUS (1000 cSt)

55 SUS (10 cSt)

-13° F to 195° F

Dexron III

ISO Approved Hydraulic

Fluid

4650 SUS (1000 cSt)

55 SUS (10 cSt)

-13° F to 195° F

Dexron III

ISO Approved Hydraulic

Fluid

4650 SUS (1000 cSt)

55 SUS (10 cSt)

-13° F to 195° F

Hoses

Motor Inlet

All Others

JIC STD

4000 psi, SAE

1250 psi, SAE

SAE

6000 psi, SAE

1250 psi, SAE

SAE

6000 psi, SAE

1250 psi, SAE

Fittings

SAE SAE SAE

Dry Weight

(without pump)

485 lbs

580 lbs

715 lbs

Dimension of Tray

Asm.

40.5” L x 19” W x 22” H

(Including Reservoir)

46” L x 19” W x 22” H

(Including Reservoir)

48” L x 19” W x 22” H

(Including Reservoir)

Ambient Operating

Temperature Range

0

°F to 120°F 0°F to 120°F 0°F to 120°F

Table 1 (cont.)



Note : The recommended PTO ratio is 1.29 : 1 (129%).
The recommended engine idle speed with this PTO is 750 RPM.
This will result in a 968 RPM pump drive input, thereby insuring 5KW
of available power at engine idle. If full output is required at idle speed, then a higher PTO
ratio must be chosen to create 1200 RPM pump drive at idle speed; however care must
be taken to prevent higher engine speeds from creating a pump speed that exceeds the
pump’s maximum speed.