Never operate the system with leaks of any type. Clean up any hydraulic fluid that is
spilled or has leaked out of the system. Hydraulic fluid is combustible, and ignition may
occur.

With the exception of instructions within this manual, never modify or remove any of the
components within the tray assembly.

Never modify or remove any of the components within the pump or the controls mounted
to the pump. This includes all fittings and tubing that are originally provided with the A.C.
modular generator system.

Never make any adjustments to the pump other than for flow control. If it appears the
pump needs to be adjusted, contact Smart Power

®

Systems at (231) 832-5525 before

proceeding. Damage to the generator from improper pump adjustment will void the
system’s warranty.

Never attempt any adjustments or repairs to the A.C. modular generator system (other
than pump flow control) or to the rescue tool system while the vehicle engine is running
and the PTO is engaged.

Never operate the system with the hydraulic fluid exceeding 195

°

F. Above this

temperature, hydraulic fluid can rapidly oxidize and deteriorate causing generator
performance problems. Operating the system while the hydraulic fluid is above 195

°

F will

void the system’s warranty.

Hydraulic fluid is combustible and toxic. In the event of human contact with hydraulic fluid,
generously flush body part (eyes, skin, etc.) with running water. Avoid inhalation of any oil
mist or vapor. Do not ingest hydraulic fluid. In case of fire, use foam, dry chemical or
carbon dioxide to extinguish flame.

Do not exceed the wattage rating of the generator. The generator may be permanently
damaged and the generator and hydraulic components may reach temperatures that could
cause severe burns upon human contact with the components. Operating the generator
system at wattages above the system’s rating will void the system’s warranty.

Disengage the system immediately if a hydraulic fluid leak is detected. Operation of the
A.C. modular generator system or the XRT rescue tool pump with low fluid level will result
in permanent damage to the hydraulic components in the system and will void the
system’s warranty.

Do not tamper with the hydraulic fluid level sensor.

Never attempt to operate the A.C. modular generator system or the XRT rescue tool pump
without hydraulic fluid. FOR A.C. Modular Generator System ONLY: A) Always
maintain a fluid level between ½ to ¾ full in the sight plug. B) When installing the system,