Smart Power Systems Liberator Series User Manual

Page 29

Advertising
background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 28 of 54

12.

Set “auto-start” option.

If the auto-start option is enabled, the generator will begin generating electricity
whenever the PTO is engaged. If the auto-start option is disabled, the generator
will not output electricity after PTO engagement until the “on/off” switch is pressed.
Select the auto-start function by performing the following steps:

Step b: Hold Mode until
Amps Line 1 Blinks

88.

Release switch so

0Pt

and AStr appear.

Step c: Press On/Off
until the desired value
appears

Figure 15


Enabling Auto-Start Option

a. If the Command & Control Center is dark, press the Mode switch to put the

Command & Control Center into Normal mode.


b. Press and hold the Mode switch until the Amps Line 1 field begins blinking

88

(more than 10 seconds). Release the switch so

0Pt and AStr appear.

Reference Figure 15.

c. Press the On/Off switch until the desired value appears. A

y means Auto-Start

is enabled, an

n means Auto-Start is disabled.

d. Return to Normal mode by pressing Mode.