A. C. MODULAR GENERATOR SYSTEM

Page 35 of 54

Message advising the
oil is cold (less than
40

°F)

Measured oil
temperature in
degrees fahrenheit

Example of Command & Control Center

when operating with cold hydraulic fluid

Figure 24



Operating Modes when the system START button is activated (or when the system is in
“autostart”):

• When the meter displays hydraulic oil temperatures below 20°F, the hydraulic

system will bypass the generator motor and the generator will not produce
power. This mode warms the hydraulic oil.


• When the meter displays hydraulic oil temperatures between 20° and 40°F, the

generator rotor will turn at a reduced RPM and the generator will not produce
power. This warms the hydraulic oil to 40

°F.

• When the meter displays hydraulic oil temperatures that exceed 40°F, the

system will then commence full power generating operations.

Maintenance Instructions

For A.C. Modular Generator System

(Reference XRT Manual for Maintenance Instructions of rescue tool pump system)


WARNING:


Do not perform maintenance while system is running.

1.

Perform regular, periodic checks to verify:

a. The cooler, the cooler fan and generator vents are not plugged by debris.
b. There are no fluid leaks within the framework of the generator, along the hoses,

or at the pump.

c. The hoses are not cut, chaffed, bulged or kinked.
d. That no electrical connections are loose.