Smart power – Smart Power Systems Liberator Series User Manual

Page 9

Advertising
background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 8 of 54

PROP. CONTROL VALVE

P/N 8594452

ASM, OIL TEMP. SENSOR

P/N 3310736

INDICATOR BULB

REMOTE ENB. SW.

NOT PROVIDED

BUZZER

W ARNING:
12 VOLTS DC MUST BE DIRECTLY APPLIED TO THE GENERATOR SYSTEM
CONTROLLER W HENEVER THE HYDRAULIC PUMP IS ENGAGED. FAILURE
TO DO SO MAY CAUSE EXCESSIVE FLUID TEMPERATURE, DAMAGING THE
SYSTEM COMPONENTS AND W ILL VOID THE W ARRANTY

VEHICLE +12V SUPPLY

VEHICLE GROUND

SYSTEM CONTROLLER

P/N 8505034 (LI-15)

P/N 8505033 (LI-20, LI-25)

BROWN/WHITE

RED

ORANGE

BLACK

ORANGE

GREY

YELLOW

PURPLE

BLACK/WHITE

GREEN/WHITE

YELLOW

BLACK/YELLOW

BLACK

GREEN

PINK

BLUE

PRESSURE SWITCH

P/N 8594019

YELLOW

PURPLE/YELLOW

ASM, OIL LEVEL SENSOR

P/N 3320106

SPS DISPLAY WIRE HARNESS

P/N 3722004

COMMAND & CONTROL CENTER

P/N 1500047

+

-

FAN MOTOR

CURRENT TRANS.

P/N 1500035

WHITE/RED

WHITE/BLUE

PINK

BLUE

PURPLE/WHITE

RED/WHITE

BLUE/WHITE

ORANGE/WHITE

CIRCUIT BREAKER

GENERATOR

OUTPUT

LOGIC HI L1
LOGIC LO L2

F1
F2

ASM, FIELD CONTROL

P/N 3100308

VAC

FIELD WINDING

RED

BLACK

CIRCUIT BREAKER

CURRENT TRANS.

P/N 1500035

GENERATOR

WINDING A

WINDING B

FIELD

T1
T2

T3
T4

GENERATOR

OUTPUT

GENERATOR

OUTPUT

GENERATOR

OUTPUT

RED

GREEN

WHITE

BLACK

Electrical Wiring Diagram for LI-15, LI-20, and LI-25 generator systems (excluding Rescue tool pump system)

Figure 2

Advertising