ThingMagic M6e User Manual

Page 31

Advertising
background image

Power Requirements

A D I V I S I O N O F T R I M B L E

Hardware Overview

31

in the

Power Management

section.

M6e Power Consumption

Operation
Power/Transmit Mode

RF Transmit

Power

Setting

(dBm)

Max Power

1

(Watts)

Voltage

(Volts)

Current

(mA)

Transmit CW
Transmit Mode = DRM

+31.5

7.5

2

5.0 +/- 5%

1400

Tag Reading
Transmit Mode = DRM

+31.5

7.5

2

5.0 +/- 5%

1400

Tag Reading
Transmit Mode = Power Save

+30

5.8

5.0 +/- 5%

1060

Tag Reading
Transmit Mode = DRM + PreDistortion

+30

6.2

5.0 +/- 5%

1200

Tag Reading
Transmit Mode = DRM

+17 and below

4

5.0 +/- 5%

800

No Tag Reading (M6e idle)
Power Mode = FULL

N/A

0.35

5.0 +/- 5%

60

No Tag Reading (M6e idle)
Power Mode = MINSAVE

N/A

0.12

5.0 +/- 5%

20

No Tag Reading (M6e idle)
Power Mode = SLEEP

N/A

0.005

5.0 +/- 5%

1.0

Boot

N/A

0.12

5.0 +/- 5%

20

Shut Down

N/A

< 0.001

5.0 +/- 5%

< 200uA

In Rush Current and Power, M6e
Power up and/or any state change

N/A

7.5

5.0 +/- 5%

1500 Max

Note:

1 - Power consumption is defined for TTL RS232 operation. Power consumption may

vary if the USB interface is connected.

Note:

2 - Power consumption is defined for operation into a 17dB return loss load or better.

Power consumption may increase, up to 8.2W, during operation into return losses
worse than 17dB and high ambient temperatures.

Advertising