Fault_general_tag_error – 40ah, Cause, Solution – ThingMagic M6e User Manual

Page 77: Fault_data_too_large – 40bh, Fault_protocol_invalid_kill_password – 40ch, Fault_protocol_kill_failed - 40eh, Fault_general_tag_error – 40ah 77, Fault_data_too_large – 40bh 77, Fault_protocol_invalid_kill_password – 40ch 77, Fault_protocol_kill_failed - 40eh 77

Advertising
background image

Protocol Faults

Appendix A: Error Messages

77

FAULT_GENERAL_TAG_ERROR – 40Ah

Cause

This error is used by the GEN2 module. This fault can occur if the read, write, lock, or kill
command fails. This error can be internal or functional.

Solution

Make a note of the operations you were performing and contact ThingMagic at

http://

support.thingmagic.com

FAULT_DATA_TOO_LARGE – 40Bh

Cause

A command was received to Read Tag Data with a data value larger than expected or it is
not the correct size.

Solution

Check the size of the data value in the message sent to the reader.

FAULT_PROTOCOL_INVALID_KILL_PASSWORD – 40Ch

Cause

An incorrect kill password was received as part of the Kill command.

Solution

Check the password.

FAULT_PROTOCOL_KILL_FAILED - 40Eh

Cause

Attempt to kill a tag failed for an unknown reason

Solution

Check tag is in RF field and the kill password.