Performance characteristics, Event response times – ThingMagic M6e User Manual

Page 62

Advertising
background image

Performance Characteristics

A D I V I S I O N O F T R I M B L E

62

Functionality of the Mercury6e

Performance Characteristics

Event Response Times

The following table provides some metrics on how long common M6e operations take. An
event response time is defined as the maximum time from the end of a command (end of
the last bit in the serial stream) or event (e.g. power up) to the response event the
command or event causes.

Event Response Times

Start Command/

Event

End Event

Time

(msecs)

Notes

Power Up

Application Active (with
CRC check)

1500

This longer power up period should only
occur for the first boot with new firm-
ware.

Power Up

Application Active

120

Once the firmware CRC has been veri-
fied subsequent power ups do not
require the CRC check be performed,
saving time.

Tag Read

RF On

20

When in Power Mode = FULL

Tag Read

RF On

50

When in Power Mode = MINSAVE

Tag Read

RF On

120

When in Power Mode = SLEEP

Change to MINSAVE

PowerMode.MINSAVE

5

From Power Mode = FULL

Change to SLEEP

PowerMode.SLEEP

5

From Power Mode = FULL

Advertising