Installation

Plumbing Requirements

The DI series dryer can be equipped with an optional fire suppression system to reduce
the risk of fire in your dryer. If so equipped, connect the water supply to the 3/4” NPT
connection, located on the rear of the machine as labeled.

90C / 195F MAX

0.7-7.0 BAR / 10-100 PSI

If fire suppression activates, the blower will stop, the cylinder will rotate in the forward
direction, and the emitters will lightly mist the goods until the temperature drops to a
safe level.

To avoid fires, keep the equipment clean, as detailed elsewhere in this manual, and
always program cool down time. No cool down time, or stopping the machine before

the cycle has completed can cause fires, as spontaneous combustion can occur in the
drying cylinder.

Prior to installation, check all local codes and permits. Call your local water company or
the proper municipal authority for information regarding local codes.

It is your responsibility to have ALL plumbing connections made by a qualified
professional to assure that the plumbing installation is adequate and conforms to local,
state, and federal regulations or codes.

It is the installation or owners responsibility to see that the necessary or required water,

water pressure, pipe size, or connections are provided. Manufacturer assumes no

responsibility if the fire suppression system is not connected, installed, or maintained
properly.