G. STEAM INFORMATION

It is your responsibility to have All steam plumbing connections made by a qualified

professional to assure that the installation is adequate and conforms with local and state

regulations or codes.

IMPORTANT: Failure to comply with the requirements stipulated in the

manual can result in component failure, which will VOID

THE WARRANTY.

NOTE: The DI-225 is manufactured with a pneumatic (piston) damper

system, which requires an external supply of air (80 psi +/- 10 psi).

See Steam Damper Air System Connections Section H item 3.

1. STEAM REQUIREMENTS, High Pressure

A. Inlet ---- 2-inch supply line connection.

B. Return --- 2-inch return line connection.

Operating Steam Pressure, High Pressure

Maximum

125 psig

8.79 kg/sq cm

Minimum

100 psig

7.03 kg/sq cm

Heat Input (Normal Load)

27 Bhp

Consumption

(Approximate)

800 lbs/hr

362 kg/hr

2. INSTALLATION INSTRUCTIONS

To insure that an adequate supply of steam is provided, be sure that the steam return lines are

sized and laid out as stipulated in this manual. Inadequate steam and steam return lines or

improper steam plumbing will result in poor performance and can cause component failure.

Clean, dry steam must be provided to the dryer.

IMPORTANT: Steam coil failure due to water hammer by wet steam

VOIDS WARRANTY.

A. The pressure of the condensate in the steam supply will cause water hammer and

subsequent heat exchanger (steam coil) failure. The steam supply connection into the main

supply line must be made with a minimum 10-inch riser. This will prevent any condensate

from draining towards the dryer.

B. The steam supply piping to the dryer must include a 12-inch rise along with a drip trap and

check valve. This will prevent any condensate from entering the steam coil.

C. Flexible hoses or couplings must be used. The dryer vibrates slightly when it runs and this

will cause the steam coil connections to crack if they are hard piped to the supply and return

mains.