B&C Technologies DI-225 Industrial User Manual

Page 37

Advertising
background image

SECTION 7

TROUBLESHOOTING

IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE

GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS

ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING,

ADJUSTING, INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA

( Occupational Safety and Health Administration ) STANDARDS.

The information provided will help isolate the most probable component (s) associated

With the difficulty described. The experienced technician realizes, however, that a Loose

connection or broken/shorted wire may be at fault where electrical components

are concerned…not necessarily the suspected component itself. Electrical parts should always

be checked for failure before being returned to the factory.

IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the

fuse being replaced. The information provided should not be misconstrued as

a handbook for use by an untrained person in making repairs

WARNING: ALL SERVICE AND TROUBLESHOOTING SHOULD BE PERFORMED

BY A QUALIFIED PROFESSIONALOR SERVICE AGENCY.

WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS

DISPLAYED ON THE DRYER OR SPECIFIED IN THIS MANUAL

A. No display…

1. Service panel fuses blown or tripped breaker

2. Blown FU1 fuse 1 or FU2 fuse 2

3. Failed microprocessor controller (computer)

B. Drive motor not operating (does not start)…

* Microprocessor controller (computer) relay output indicator (either) forward

“FWD” or reverse “REV” is on

1. Blown drive motor contactor fuse (s)

2. Failed drive motor contactor

3. Failed drive motor

4. Failed soft start

* Microprocessor controller (computer) relay output indicator (neither) forward

“FWD” or reverse “REV” go on

1. Failed microprocessor controller (computer)

Advertising