Motor protection, Dip switch – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 115

Advertising
background image

Operating Instructions – MOVIMOT® MM03C - MM3XC

115

8

Additional information for mounting close to the motor

Startup with Integrated AS-Interface

8.8

Additional information for mounting close to the motor

Observe the following instructions when mounting the MOVIMOT

®

inverter with option

P2.A close to the motor:

Checking the
method of con-
nection for the
connected motor

Use the following figure to verify that the selected connection method of MOVIMOT

®

is

identical for the connected motor.

Important: For brake motors: Do not install brake rectifiers inside the terminal box
of the motor!

Motor protection

The connected motor must be equipped with a TH. SEW recommends wiring the TH via
input DI2 (see the following figure).

Input DI2 must be monitored be an external control.

As soon as DI2 = LOW, the drive must be switched off (bit D0 and D1 = "0").

DIP switch

With mounting of the MOVIMOT

®

inverter close to the motor, set DIP switch S3/1 to ON

which is different than the factory setting.

03636AXX

U1

V1

W1

W2 U2 V2

U1

V1

W1

W2 U2 V2

Ħ

52254AXX

24V

DI2

TH

MOVIMOT

®

S3

1

2

3

4

5

6

Message

Motor

protection

Motor

rating class

PWM

frequency

No-load

damping

Motor type

Brake release

without

Enable

ON

Off

Motor one

size smaller

Variable

(16, 8, 4

kHz)

On

SEW DZ

motor:

1)

1) only available in Brazil

On

OFF

On

adapted

4 kHz

Off

IEC motor

Off

0

0

I

Advertising