Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 138

Advertising
background image

138

Operating Instructions – MOVIMOT® MM03C - MM3XC

10

Diagnostics of MOVIMOT® with integrated AS-Interface

Diagnostics

"Monitor" window
description

The following illustration shows the diagnostic monitor.

AS-i communication window area

The "Inverter status" window area displays important information about the status of
the AS-Interface. The AS-i control outputs window area displays the current status of
the AS-i bits "D0 (CW/stop)", "D1 (CCW/stop)", "D2 (Setpoint f1/f2)" and "D3 (Reset/
controller inhibit)". An AS-i bit set by the master is identified by a green symbol.

The "AS-i parameters" window area displays the current status of the AS-i parameter
bits. These bits are used to select the scaling factor. An AS-i parameter bit set by the
master is identified by a green symbol.

The "MOVIMOT

®

parameters" window area displays information about the current

speed setpoint, the active scaling factor selected (via AS-i parameter bits) and the
ramp time selected via switch t1.