Startup with MWA21A option (speed control module)

Startup of Standard Design

7. Place the MOVIMOT

®

inverter on the terminal box and secure it.

8. Set the required maximum speed using setpoint potentiometer f1.

9. Re-insert screw plug of setpoint potentiometer f1 with gasket.

10.Select the signal type for the analog input (terminals 7 and 8) of the MWA21A option

using switches S1 and S2.

11.Switch on the voltage.

12.Release MOVIMOT

®

by applying +24 V to tl. 4 (CW rotation) or tl. 5 (CCW rotation)

of the MWA21A.