Operating Instructions – MOVIMOT® MM03C - MM3XC

153

12

Integrated RS-485 interface

Technical Data of Standard Design

URM voltage
relay

12.4

Integrated RS-485 interface

12.5

Assignment of internal braking resistors

Voltage relay

Part number

827 601 3

Function

Implements quick application of mechanical brake

Enclosure

IP20

Rated voltage V

rated

36 V

DC

...167 V

DC

(brake coil 88 V

AC

...167 V

AC

)

Brake current I

N

0.75 A

Ambient temperature

-25...60 °C

Switch-off time t

off

(separation on DC

side)

approx. 40 ms

RS-485 interface

Standard

RS-485 to EIA standard (with integrated dynamic terminating resistor)

Baud rate

9.6 kbaud
31.25 kbaud (in conjunction with fieldbus interfaces MF..)

Start bits

1 start bit

Stop bits

1 stop bit

Data bits

8 data bits

Parity

1 parity bit, supplementing to even parity

Data direction

Unidirectional

Operating
mode

Asynchronous, half-duplex

Timeout inter-
val

1 s

Line length

max. 200 m in RS-485 operation at 9,600 baud
Max. 30 m with transmission rate: 31,250 baud

1)

1) Transmission rate 31,250 baud is detected automatically when operating with fieldbus interface MF...

Number of
stations

max. 32 stations (1 bus master

2)

+ 31 MOVIMOT

®

) broadcast and group addresses

possible

15 MOVIMOT

®

individually addressable

2) Ext. control or MBG11A, MWA21A or MLG..A option

MOVIMOT

®

type

Braking resistor

Part number

MM03 to MM15

BW1

822 897 3

1)

1) Two screws M4 x 8, included in delivery

MM22 to MMM3X

BW2

823 136 2

1)

P

i

f

kVA

Hz

n

Advertising