Use the seals (3) to close the mounting

holes on the sensing face of the safety

switch.

Orthogonal assembly

Drill holes in the mounting surface (see

Di-

mensions [

19]

) and cut threads in the

holes for M4 screws.

Use a screw to fix the safety switch in place.

1. Do not fully tighten the 2nd screw on the

safety switch.

2. Attach the screws for the actuator, leav-

ing a distance of 3 … 6 mm between the
screw head and plate.

For the next steps you will need the seals as

illustrated.

Use the seals (2) to close the unused

mounting holes on the actuator.

Slide the actuator on to the screws.