Error display through flashing codes – Pilz PSEN cs4.1a User Manual

Page 18

Advertising
background image

PSEN cs4.1a/b/p/M12

Operating Manual PSEN cs4.1a/b/p/M12
22187-EN-02

18

Error display through flashing codes
The "Safetygate" and "Input" LEDs send flash signals; an error code can be established
from the number and sequence. The "Power/Fault" LED illuminates red.
Each error code is indicated by three short flashes of the "Input" or "Safetygate" LED. After
a longer pause, the LED will then flash at one second intervals. The number of LED flashes
corresponds to a digit in the error code. The error code can consist of up to 4 digits. The
digits are separated by a longer period without flashing. The entire sequence is constantly
repeated.

Number of flashes

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Decimal error code

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0

Example:
Error code 1,4,1:
Flash frequency of the “Safetygate” or “Input” LED

I

IV

III

II

V

Meaning of flash frequency:

Flash frequency

Meaning

I

3 times, short

Code for error message

II

Once for one second

Code for 1st digit

III

4 times, for one second each

Code for 2nd digit

IV

Once for one second

Code for 3rd digit

V

3 times, short

Code for error message repeated

Table of error codes

Error code
decimal

Number of flashes

Description

Remedy

1,4,1

3x short – 1x long –

4x long – 1x long – 3x

short

At least one of the two safety out-

puts 12 and 22 have voltage ap-

plied during system run-up

Check the wiring of safety outputs

12 and 22, rectify the wiring error

1,12

3x short – 1x long –

12x long – 3x short

During operation, short circuit be-

tween safety output 12 and 0 VDC

Rectify wiring error at safety output

12

1,13

3x short – 1x long –

13x long – 3x short

During operation, short circuit be-

tween safety output 22 and 0 VDC

Rectify wiring error at safety output

22

14

3x short – 14x long –

3x short

During operation, short circuit be-

tween safety output 12 and 24

VDC

Rectify wiring error at safety output

12

15

3x short – 15x long –

3x short

During operation, short circuit be-

tween safety output 22 and 24

VDC

Rectify wiring error at safety output

22

Advertising