19b1.5. safety information, Safety information – Pilz PSEN op4H-s-30-150/1 User Manual

Page 15

Advertising
background image

Instruction Manual

PSEN op4F/H-s Series

11

1.5. Safety information

For a correct and safe use of the safety light curtains of the

PSEN op4F/H-s series, the following points must be observed:

The stopping system of the machine must be electrically controlled.


This control system must be able to stop the dangerous movement

of the machine within the total machine stopping time T as per

paragraph 1.3.3, and during all working cycle phases.


Mounting and connection of the safety light curtain must be carried

out by qualified personnel only, according to the indications

included in the special sections (refer to sections 2; 3; 4; 5) and in

the applicable standards.


The safety light curtain must be securely placed in a particular

position so that access to the dangerous zone is not possible

without the interruption of the beams (refer section 2 “Installation

mode”).


The personnel operating in the dangerous area must be well trained

and must have adequate knowledge of all the operating procedures

of the safety light curtain.


The TEST (optional for the safety light curtains Type 4) button must

be located outside the protected area because the operator must

check the protected area during all Test operation.


The RESET/RESTART button must be located outside the

protected area because the operator must check the protected area

during all Reset/Restart operations.

Please carefully read the instructions for the correct functioning

before powering the light curtain.

Advertising