30b7.2. dagnostic messages, Dagnostic messages – Pilz PSEN op4H-s-30-150/1 User Manual

Page 45

Advertising
background image

Instruction Manual

PSEN op4F/H-s Series

41

7.2. Dagnostic messages

The operator can evaluate the main causes of the system stop or

failure through the display and signalling LEDs.

For Receiver:

Function

Status

Meaning

LED

DIGIT

Normal

operation

Alignment

See section 5

TEST
(red ON)

Light curtain being

tested. OSSD status

shall be OFF

Emission
(OSSD ON)
(green ON)

Light curtain working in

normal operating

conditions

Interruption
(OSSD OFF)
(red ON)

Light curtain working in

safety block conditions.

Interlock
Beams free
(red ON
yellow ON)

Light curtain in

interlock, waiting for

restart. OSSD status

must be OFF

Interlock
Beams

interrupted
(red ON
yellow ON)

Light curtain in

interlock. OSSD status

must be OFF

Signal level

Minimum (1 bar)
Medium (2 bar)
Maximum (3 bar)

EDM enabled

EDM function is

selected