PSEN op4F/H-s Series

21

The operator must respect the following precautions when using the

deviating mirrors:

The alignment of the emitter and the receiver can be a very critical

operation when deviating mirrors are used. Even very small

displacements of the mirror is enough to lose alignment. The use of

Pilz laser pointer accessory is recommended under these

conditions.

The minimum safety distance (S) must be respected for each single

section of the beams.

Use of a deviating mirror reduces the effective operating range by

about 15%. This percentage increases further when using two or

three deviating mirrors.

In the table below the operating ranges are indicated, based on the number
of the mirrors used.

Number of
mirrors

Operating range

Operating range

Without mirror 6 m

19 m

1

5.1 m

16.5 m

2

4.3 m

13.7 m

3

3.7 m

11.6 m

The presence of dust or dirt on the reflecting surface of the mirror

causes a drastic reduction in the range.

2.2.6. Controls after first installation

The control operations to carry-out after the first installation and

before machine start-up are listed hereinafter. The controls must be

carried-out by qualified personnel, either directly or under the strict

supervision of the person in charge of machinery Safety.

Verify that:
AOPD remains blocked (

) intercepting the beams along the

protected area using the specific test piece, following the Fig.12

scheme.

TP14 for light curtains with 14 mm resolution: PSEN op4F-s-14

TP30 for light curtains with 30 mm resolution: PSEN op4H-s-30