24b5.1. correct alignment procedure, Correct alignment procedure – Pilz PSEN op4H-s-30-150/1 User Manual

Page 38

Advertising
background image

PSEN op4F/H-s Series

Instruction Manual

34

The standard installation described hereinafter is the one shown in

Fig. 22, i.e. with the bar assembled with the connectors pointing

down.

5.1. Correct alignment procedure

The light curtain alignment can be effected only after having

completed the mechanical installation and the electrical connections

as described above. Compare alignment results with those given in

the following table.

NOTE: To enter alignment mode connect the device as described in

section 6.5 “Alignment aid function”.

Display

LED

NORMAL

OP.

LED

SAFE

(BREAK)

LED

yellow

SYNC

LED

yellow

LAST

Condition

Alignment

status

OFF

ON

ON

ON

Sync

NOK

Last NOK

Not

aligned

OFF

Sync

OK

Last NOK

OFF

OFF

Sync

OK

Last NOK

Middle optics NOK

ON

OFF

OFF

OFF

Each beam is over

the min. operating

threshold and the

number of beam over

the threshold is

included between

0 and 25%

MINIMUM

align.

ON

OFF

OFF

OFF

Each beam is over

the min. operating

threshold and the

number of beam over

the threshold is

included between

25 and 50%

ON

OFF

OFF

OFF

Each beam is over

the min. operating

threshold and the

number of beam over

the threshold is

included between

50 and 75%

ON

OFF

OFF

OFF

Each beam is over

the min. operating

threshold and the

number of beam over

the threshold is

included between

75 and 100%

MAXIMUM

align.

Advertising