PNOZ s3

Operating Manual PNOZ s3
21395-EN-10

3

PNOZ s3 safety relay

The safety relay provides a safety-related interruption of a safety circuit.
The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1
and may be used in applications with

}

E-STOP pushbuttons

}

Safety gates

}

Light beam devices

For your safety

}

Only install and commission the unit if you have read and understood these operating

instructions and are familiar with the applicable regulations for health and safety at work
and accident prevention.
Ensure VDE and local regulations are met, especially those relating to safety.

}

Any guarantee is rendered invalid if the housing is opened or unauthorised modifica-

tions are carried out.

Unit features

}

Positive-guided relay outputs:

– 2 safety contacts (N/O), instantaneous

}

1 semiconductor output

}

Connection options for:

– E-STOP pushbutton
– Safety gate limit switch
– Start button
– Light beam device
– PSEN

}

A connector can be used to connect 1 PNOZsigma contact expansion module

}

Operating modes can be set via rotary switch

}

LED indicator for:

– Supply voltage
– Input status, channel 1
– Input status, channel 2
– Switch status channel 1/2
– Start circuit
– Error

}

Plug-in connection terminals (either spring-loaded terminal or screw terminal)

Advertising