Safety features

The relay meets the following safety requirements:

}

The circuit is redundant with built-in self-monitoring.

}

The safety function remains effective in the case of a component failure.

}

The correct opening and closing of the safety function relays is tested automatically in

each on-off cycle.

}

The unit has an electronic fuse.

Block diagram/terminal configuration

Input

Input

A1 A2

S21 S22

=

Power

Reset/

Start

S34

S11 S12

=

Y32

K1

K2

13 23

24

14

Interface expansion

unit

*

Centre: Front view with cover, right: Front view without cover

*Insulation between the non-marked area and the relay contacts: Basic insulation (overvolt-
age category III), safe separation (overvoltage category II)

Function description

}

In2+

Single-channel operation: no redundancy in the input circuit, earth faults in the start

circuit and input circuit are detected.

}

Dual-channel operation without detection of shorts across contacts: redundant input cir-

cuit, detects
– earth faults in the start and input circuit,
– short circuits in the input circuit and, with a monitored start, in the start circuit too.

}

In2-

Dual-channel operation with detection of shorts across contacts: redundant input cir-

cuit, detects
– earth faults in the start and input circuit,
– short circuits in the input circuit and, with a monitored start, in the start circuit too,
– shorts between contacts in the input circuit.

}

Automatic start: Unit is active once the input circuit has been closed.