Table 3-10. DataCORDER Pre-Trip Data

TEST #

TITLE

DATA

NOTE

“Auto” or “Auto1” menu includes the following: P, P1, P2, P3, P4, P5, P6 and rSLts. “Auto2’ (Optional)

menu includes the following: P, P1, P2, P3, P4, P5, P6,P7, P8, P9, P10 and rSLts. (Refer to section 3.2.1.)

1-0

Heater On

Pass/Fail/Skip Result, Change in current for Phase A, B and C

1-1

Heater Off

Pass/Fail/Skip Result, Change in currents for Phase A, B and C

2-0

Condenser Fan On

Pass/Fail/Skip Result, Water pressure switch (WPS) -- Open/Closed,

Change in currents for Phase A, B and C

2-1

Condenser Fan Off

Pass/Fail/Skip Result, Change in currents for Phase A, B and C

3-0

Low Speed Evaporator Fan

On

Pass/Fail/Skip Result, Change in currents for Phase A, B and C

3-1

Low Speed Evaporator Fan

On

Pass/Fail/Skip Result, Change in currents for Phase A, B and C

4-0

High Speed Evaporator Fan

On

Pass/Fail/Skip Result, Change in currents for Phase A, B and C

4-1

High Speed Evaporator Fan

On

Pass/Fail/Skip Result, Change in currents for Phase A, B and C

5-0

Supply/Return Probe Test

Pass/Fail/Skip Result, STS, RTS, SRS and RRS

5-1

Secondary Supply Probe Test Pass/Fail/Skip Result

5-2

Secondary Return Probe Test

Pass/Fail/Skip Result

6-0

Compressor On -- High Speed Pass/Fail/Skip Result, Change in currents for Phase A, B and C

6-1

Compressor On -- Low Speed Pass/Fail/Skip Result, Change in currents for Phase A, B and C

6-2

Suction Modulation Valve

Open

Pass/Fail/Skip Result, STS, RTS, Is current limit in effect? (Y,N)?

6-4

Suction Modulation Valve

Closed

Pass/Fail/Skip Result, STS, RTS, Delta T1, Delta T2,

Is current limit in effect? (Y,N)?

6-5

Suction Solenoid Valve Open

Pass/Fail/Skip Result, STS, RTS, Is current limit in effect? (Y,N)?

7-0

High Pressure Switch Closed

Pass/Fail/Skip Result, AMBS, DPT or CPT (if equipped)

Input values that component opens?

7-1

High Pressure Switch Open

Pass/Fail/Skip Result, STS, DPT or CPT (if equipped)

Input values that component closes?

8-0

Perishable Heat

Pass/Fail/Skip Result, STS, time it takes to heat to 16_C (60_F)?

8-1

Perishable Pull Down

Pass/Fail/Skip Result, STS, time it takes to pull down to 0_C (32_F)?

8-2

Perishable Maintain

Pass/Fail/Skip Result, Averaged DataCORDER supply temperature

(SRS) over last recording interval.

9-0

Defrost Test

Pass/Fail/Skip Result, DTS temperature at end of test, line voltage,

line frequency, time in defrost.

10-0

Frozen Mode Set-up

Pass/Fail/Skip Result, STS, time unit is in heat.

10-1

Frozen Mode Pull Down

Pass/Fail/Skip Result, STS, time to pull down unit to --17.8_C (0_F).

10-2

Frozen Mode Maintain

Pass/Fail/Skip Result, Averaged DataCORDER return temperature

(RRS) over last recording interval.