Manage traps and alarms, Manage traps and alarms -7, Table 7. trap configuration options -7 – CANOGA PERKINS 1500 Domain Management Module User Manual

Page 19

Advertising
background image

The MAC or Ethernet hardware address for the DMM is fixed. If BOOTP is enabled during the
initialization process, it broadcasts BOOTP request packets until it receives a response from the
BOOTP server or you press <Esc> to continue. If the DMM has a fixed IP address, disable
BOOTP. To assign an IP address to the DMM through the BOOTP request process, follow these
steps:

1. At the Domain Management Module menu, type

1

; the System Configuration screen appears.

2. Check item 10, BOOTP.

• If it is set to "Enabled," reset the DMM to start the BOOTP process.
• If it is set to "Disabled," type

10

and press <Enter>, then press <Space> to cycle between

Disabled and Enabled, and then press <Enter>. The next time you reset the DMM, it will
start the BOOTP process.

3. To return to the Domain Management Module menu, press <Esc>.

Manage Traps and Alarms

Traps are messages that require management attention and are routed to the Network Manager
and the DMM Alarm Log, but do not trigger alarms. Use the Trap Configuration screen to view
the current configuration and enable log only, send only, both log and send; or disable traps
individually or use the "Master Trap Control" to set all traps for the DMM. For a list of events
that trigger traps, see Table 7. To set up the traps, follow these steps:

1. At the Domain Management Module menu, type

5

, "Trap Configuration," and press <Enter>.

2. At the Trap Configuration screen, type the number for a trap and press <Enter>. See Table 7.

3. Press <Space> to cycle to Log Only, Send Only, Both Log and Send, or Disabled and press

<Enter>.

4. To return to the Domain Management Module menu, press <Esc>.

These selections do not affect how the CIM Major and Minor LEDs report alarms.

Table 7. Trap Configuration Options

Trap

When enabled, sends a Trap if. . .

Cold Start

The DMM is reset by a power failure or forced reset

Setup Error

The DMM is set up incorrectly

Fan/Power/Over Temperature The chassis power supply or fan malfunctions or the temperature is too

high

Chassis On/Off Line

The chassis in the domain does not respond

Module Insert/Removed

A module is inserted or removed

Authentication Error

An unauthorized host attempts SNMP access to the DMM

Chassis Power Exceeded

The installed modules draw more total power than the chassis supplies

Model 1500 Domain Management Module

3-7