Manage a CIM

The CIMs can interconnect up to eight chassis in one domain. Use the CIM Management screen
to view real time and static information about the chassis. Each CIM monitors a variety of
operational parameters for the chassis that it is in, including:

• Chassis type
• Power supply status and chassis temperature
• Clock status
• Major and Minor alarms status
To access the CIM Management screen, follow these steps:

1. From the DMM Main Menu, type

5

, or "Manage or access the CIM modules," and press

<Enter>.

2. The CIM selection appears at the right of item 5; press <Space> to cycle through the options,

then press <Enter> to select a CIM. The CIM Management screen appears with information
and status for the chassis and CIM. See Figure 10.

3. To return to the Main Menu, press <Esc>.

CIM MANAGEMENT

CIM : 2

Chassis Type: 2U Chassis CIM Status: Online

Redundant Power: Yes

Primary Power Type: DC isolated CIM clock: Good

Primary Power status: Good CIM Providing Clock: Enabled

Secondary Power Type: DC isolated CIM Interlink Clock: N/A

Secondary Power Status: Good Alarm Relay Status: Major & Minor

Fan Installed: Yes Alarm Latch Status: Major & Minor

Fan Status: Good Backplane Alarm Inputs: Off

Up Link Installed: No CIM Major Alarm: Off

Down Link Installed: No CIM Minor Alarm: Off

CIM Model: 1202-2000 Chassis Temperature: OK

CIM Firmware: 3.5

CIM Serial Number: 20011195838

CIM Hardware Version: A2A

1. Reset Major and Minor Alarm Relay

Figure 10. CIM Management Screen

Note: For details on the CIM, the Alarms, and the soft reset, see the Model 1200 Chassis

Interconnect Module User Manual.

Manage a Module

If you know which chassis and slot a specific module is installed in, you can directly access and
manage it through the Module Menu. For details about a specific module, see the User Manual
for that module.

Note: You can manage most features of a module by opening the chassis management screen,

then selecting the module in the chassis; however, you cannot name a module through