Manage system status and alarms, Manage the module code library, Manage system status and alarms -19 – CANOGA PERKINS 1500 Domain Management Module User Manual

Page 31: Manage the module code library -19, Table 8. syslog message severity mask levels -19

Advertising
background image

Table 8. Syslog Message Severity Mask Levels

Severity Level

Include Message Types

About...and Higher

Example Message

Debug All

Syslog

ready

Informational

The system state during
normal operation

Log cleared
User account password changed

Notice

Minor changes that affect the
system, but operation can
continue

Remote unit offline
Fan malfunction
Unknown user attempted to login

Warning

Changes that affect the system
and its operation

System restarted
Security lockout time changed

Error

Conditions that significantly
affect system operation

Syslog failed
CAP feature not found

Critical, Alert, Emergency

None; not used

N/A

Manage System Status and Alarms

If an alarm occurs, it sets the Alarm Relays on the CIM for the chassis with the module with the
problem. The System Status screen shows general alarm and error information about the system,
such as which chassis has an alarm, as well as hardware and software data for the DMM, and
provides an option to reset all alarms relays in the system. To access the System Status screen
and reset all relays after resolving a problem, follow these steps:

1. From the Main Menu, type

8

, "System Status," and press <Enter>. The System Status screen

appears.

2. To reset all Major and Minor alarm relays in the domain, type

1

and follow the prompts on

the screen.

3. To return to the Main Menu, press <Esc>.

Manage the Module Code Library

The Module Code Library, located in the Flash Memory so that the information remains available
after power-down and power-up, can store one version of code for each module in the domain.
You may need to view or delete the Library Code files (the firmware, configuration [*.cfg], and
capabilities [*.cap] files for various modules and the DMM). To access the Code Library menu,
follow these steps:

1. From the DMM Main Menu, type

6

, or "Access Module Code Library," and press <Enter>.

The Code Library menu appears.

2. At the Code Library menu, select an option:

• To view files in the current working directory, type

1

.

• To change to another working directory, type

2

. At the prompt, enter the path to the new

directory or enter "//" to go to the top of the directory tree.

• To remove files, type

3

, and follow the prompt on screen.

• To remove a directory, type

4

, and follow the prompt on screen.

3. To return to the Main Menu, press <Esc>.

Model 1500 Domain Management Module

3-19

Advertising