Appendix

controller. Rem

even when the controller is powered on, it only heats the probe the

to gr

the black

ater functions properly whether or not yo

his connection. It is simply

a status output for your convenience.

n the probe he

ed o

g

on the pa

oth

a

ite

priate current to the LED, and can accommodate the power

AOA/PITOT PROBE MOUNTING

The Dynon Avionics AOA/Pitot probe has been designed as an under-wing pitot. The following

n. If you wish to mount your pitot on nose boom

pria

tments to your pitot. The heated version

e n

func

elatively un

d

inches below the

g edge of the win

imize the effect

hown that the

or

also w

ined, mo

d

eithe

durin

acket. Use caution when drilling the holes, ensuring

OA pressure lines. As long as you do not penetrate

ember that

amount necessary to maintain temperature.
The black wire should be permanently connected
controller should occur via the red power line, not

Heater Status Connection

Note: The probe he

ound. Cutting power to the heater

ground line.

u make t

The white heater status wire is grounded whe
properly. This wire should be connected to a light
connected to switched aircraft power. When the he
heater status line is open, leaving the indicator light tu
heater controller – or it is not functioning properly – the white line is grounded, turning the
indicator light on.
Aircraft Spruce P/N 17-410 is an example of a light that will work for this application. An LED
and resistor in series will also suffice. If you use an LED as the indicator, you must choose a
resistor that delivers the appro

ater is turn

ff or not functionin

nel, whose

er terminal is

ter is on and functioning properly, the wh

rned off. When there is no power to the

required for its current and voltage drop.
If you own a Dynon EMS-based product, you may also use one of its two contact input to
display an onscreen indication. Connect this heater status output directly to the desired EMS
contact input, with no additional resistors or lights. You must configure the contact display as
described in your EMS-based product’s Installation Guide.

information applies to this type of installatio
mount, contact us so we can make the appro
of Dynon’s AOA/Pitot Probe does not com

AOA/Pitot Probe Mount Location

The Dynon Avionics AOA/Pitot probe only
where the airflow over the probe is r
recommend that you mount it at least 6
between 2 and 12 inches behind the leadin
mounted about mid-wing span wise to min
tips. Testing during the probe development has s
the pitot probe in the RV series of aircraft

te adjus

a

-

i

boom mount configuration.

tions correctly when mounted in a location

disturbe by the aircraft. In general, we

wing and with the tip of the probe

g. Typically, pitot probes are

s of both the propeller and the wing

standard mounting locations f

orks for the Dynon probe.

unt the pitot mounting kit per the include

r case, mount the probe securely to the wing

g level flight. Drill and tap mounting holes (#6-

AOA/Pitot Probe Mounting Instructions

After the mounting location has been determ
instructions or fabricate your own mount. In
such that the body of the probe is horizontal
32) on the probe to match your mounting br
that you avoid drilling into the pitot and A

7-28

EFIS-D10A

Installation

Guide