Autopilot

Installation and Configuration

EFIS-D10A Installation Guide

6-15

 Enter the EFIS > SETUP > DSAB > CONFIGURATION menu.

ARE YOU SURE YOU WANT TO RE-CONFIGURE THE NETWORK?

 Press YES

ARE ALL NETWORKED DEVICES POWERED ON?

 Press CONFIGURE NOW

PLEASE WAIT DETECTING ALL NETWORK DEVICES

 Wait up to 1 minute

(X) DEVICES FOUND NETWORK CONFIGURATION IS COMPLETE

shows the correct numb

 Verify that this

all expected de

er of devices. If not, check wiring and ensure that

ld

t

if the EFIS is already at version 5.4

til this procedure is completed,

vices are powered on.

 Press FINISH

 Press UP▲ > and then SEL► to select the STATUS menu. The Bus Master EFIS shou

be displayed, showing active roles and status. Verify that STATUS (at bottom) shows
ACTIVE.

 Press DOWN▼ once for each device in the network. Verify that the STATUS for each

device shows ACTIVE. If the status displays UPGRADE REQ, that instrument must
be updated to the same version of firmware as the Bus Master EFIS.
If the
instrument displaying UPGRADE REQ is one or more of your servos and/or AP74 (mos
commonly when these devices were purchased separately from your EFIS), you must
perform the upgrade via the Bus Master EFIS, even
firmware.

 After the above verification, press BACK > EXIT

STEP 2 - SERVO CALIBRATION AND SERVO TEST

The Servo Calibration procedure identifies the orientation and range of motion of each servo.
The Servo Test procedure verifies that each servo is configured properly by moving the control
surfaces, and requiring the pilot to verify correct movement. Un
the EFIS does not display the AP status or operation interface.

If Airspeed Color Thresholds have not been configured, Servo Calibration and Servo T
cannot proceed, and the EFIS displays an error message. To configure Airspeed Color

est

;

ration, the SERVO TEST procedure can be performed on its own

vo has been installed, skip the non-applicable

On

 Enter the SETUP > AP > SERVO CALIB menu.

Thresholds, see Configure Airspeed Color Thresholds on page 4-7.

Note: Servo calibration (SERVO CAL) and servo test (SERVO TEST) is a combined procedure
when Servo Calibration is completed successfully, you are prompted to perform Servo Test.
After a successful servo calib
whenever desired.

Note: The following steps assume that two servos are installed to provide AP control of Pitch
and Roll functions. If only a Pitch or Roll ser
sections.

the EFIS, perform the following: