Network status, Network status -5 – Dynon Avionics EFIS-D10A Installation Guide User Manual

Page 39

Advertising
background image

DSAB

Configuration

EFIS-D10A Installation Guide

5-5

AP

ROLL/PITCH

SERVO

 Roll Servo and Pitch Servo functions are automatically detected and

assigned during Autopilot Servo Calibration process. See: EFIS > SETUP
> AP > SERVO CALIB.

 More than two SV32s or SV42s is not a supported configuration.

If the configuration process could not automatically assign the EMS and OAT roles (because
there are 2 or more of either type found on the network), it prompts you to assign each of them to
the instrument of your choice. It then presents a list of all instruments on the network capable of
being assigned each role. Use the DOWN▼ and UP▲ buttons to select the preferred instrument
to provide the given role. The serial number for each unit is displayed next to its product type.
Additionally, with an instrument type selected, pressing IDENT changes that instrument’s
display to a black screen with the text DSAB IDENT shown. If the instrument you wish to
identify is the one which you are currently interacting with, the line changes to read THIS UNIT.
When you have selected the preferred provider for the role, press SELECT to continue in the
process. If necessary, repeat with the next manually assigned role.
At this point, a screen is displayed, stating:
(X) DEVICES FOUND
NETWORK CONFIGURATION IS COMPLETE
Press FINISH to end the configuration. Press UP▲ and SEL► to view the status of all
connected DSAB devices. Press UP▲ or DOWN▼ to scroll through all the devices. Cross-
check the displayed devices against what you actually have installed and connected. Ensure that
the STATUS for each device is listed as ACTIVE.
You may repeat the configuration process as many times as you wish. Whenever you add or
remove an instrument from your network, you must redo the DSAB configuration process.

Note that the following DSAB configurations are not supported:

 More than 1 FlightDEK-D180 in the network

 More than 1 HS34 in the network

 More than 1 AP74 in the network
 More than 2 servos in the network

Network Status

The STATUS submenu displays information
on all configured devices, their serial
numbers, their roles on the network, and
their status.
The first line indicates how many devices
are configured on the network. This number
is independent of the number of devices
actually currently turned on and
communicating. It simply reports how many
instruments were present during the most
recent execution of DSAB configuration.