B. WIRING

FIELD CONNECTION WIRING

TABLE 4

UNIT WIRING

TABLE 5

WIRE COLOR

CONNECTION TERMINALS

CIRCUIT DESCRIPTION

Black

L1 and L2 terminals on main terminal block.

Right heating element

circuit. (Charge circuit #1)

Red

L1 and L2 terminals on auxilliary terminal block.

Left heating element

(512 and 612 units only)

circuit. (Charge circuit #2)

Blue

F1 and F2 terminals on main terminal block

Fan and control circuit.

with S series only. F1 and F3 terminals on main

terminal block with EXT series only.

Orange

A1 and A3 terminals on main terminal block

Automatic charge

with S series only.

control circuit.

See Unit Identification Label on lower right side of unit for proper fan and element voltages.

NOTES:

1. 512 and 612, S and EXT series

units, are equipped with a two
circuit element feed option. If
dual feed is used, see unit identi-
fication label located on right
side panel for proper sizing of
each circuit. Charge Circuit #1 +
Charge Circuit #2 = Total Watt-
age.

2. The field connection wire size

guide reflects only the code inter-
pretation of Steffes ETS. It is the
responsibility of the installer to
follow all applicable codes and
regulations for the installation.

MAXIMUM kW

240VAC

277VAC

208VAC

#14 AWG

2.8

3.3

2.4

#12 AWG

3.8

4.4

3.3

#10 AWG

5.7

6.6

4.9

#8 AWG

7.6

8.8

6.6

#6 AWG

11.5

13.2

9.9

WIRE

SIZE

UNIT IDENTIFICATION LABEL

FIGURE 7

Model

Charge Crct #1

S/N

Charge Crct #2

Options

Fan/Cntrl Crct

U.S. Patent #5.042.081

U.S. Patent #5.042.081

U.S. Patent #5.042.081

U.S. Patent #5.042.081

U.S. Patent #5.042.081

Temp Cntrl Crct

Electric

Electric

Electric

Electric

Electric

Air Heater

Air Heater

Air Heater

Air Heater

Air Heater

Steffes ETS, Dickinson, ND

Steffes ETS, Dickinson, ND

Steffes ETS, Dickinson, ND

Steffes ETS, Dickinson, ND

Steffes ETS, Dickinson, ND

Manufactured in U.S.A.

VAC

VAC

VAC

VAC

VAC

Watts

Watts

Watts

Watts

Watts

UL

UL

LISTED

LISTED

LISTED

LISTED

LISTED

3P23

3P23

3P23

3P23

3P23

C

Use copper wire rated at 75

o

C minimum, only.

Advertising