Jumper Configurations

Jumper

Connections

J-1

Connected with a jumper in all modes except when using automatic charge control with two-mode circuit boards.

J-2

Always connected with jumper.

J-3

Connected with violet jumper except when fans are to be disabled during the charge period.

J-4

Input voltage selector: When fan circuit input voltage is 208-240 VAC,
J4-2 to J4-3 are connected. When fan circuit input voltage is 120 VAC, J4-1 to J4-2 and J4-3 to J4-4 are connected.

J-5

Factory wired with plug-in header connector.

J-6

Fan run time based charging jumper: In OP. MODE #1, off-peak heat call can bring core to a 1/3 charge level when no
other charging method is being used. OP. MODE #2 will allow off-peak heat calls to bring core to full charge. OP. MODE
#3 will not allow core charging based on fan run time (positive off).

J-7

24 VDC output from circuit board used for auxiliary control devices or to run peak and pre-peak signals on DC power
rather than AC power.

J-8

When connected, enables fans during pre-peak charging mode.

CIRCUIT BOARD FACE PLATES - EXT SERIES

CHARGE CONTROL CIRCUIT BOARD CONFIGURATORS - EXT SERIES

Multi-Mode Circuit Board Configurator

FIGURE 23

Two-Mode Circuit Board Configurator

FIGURE 24

(NOTE:

When reading the Typical System Wiring Diagrams and Unit Wiring Diagrams, use

these skematics to determine which circuit board your heater incorporates.)

~ C

~ C

~ C

~ C

~ C

OMFOR

OMFOR

OMFOR

OMFOR

OMFORT

T

T

T

T

Z

Z

Z

Z

Z

O

O

O

O

ONE

NE

NE

NE

NE

~

~

~

~

~

85

85

85

85

85

55

55

55

55

55

O

O

O

O

O N

N

N

N

N

OFF

OFF

OFF

OFF

OFF

HIGH

HIGH

HIGH

HIGH

HIGH

M E D

M E D

M E D

M E D

M E D

LO

LO

LO

LO

LOW/A

W/A

W/A

W/A

W/AUTO

UTO

UTO

UTO

UTO

HEA

HEA

HEA

HEA

HEAT

T

T

T

T

STORA

STORA

STORA

STORA

STORAGE

GE

GE

GE

GE

CHARGE

CHARGE

CHARGE

CHARGE

CHARGE

LEVEL

LEVEL

LEVEL

LEVEL

LEVEL

OFF-PEAK

OFF-PEAK

OFF-PEAK

OFF-PEAK

OFF-PEAK

CHARGING

CHARGING

CHARGING

CHARGING

CHARGING

O

O

O

O

O N-PEAK

N-PEAK

N-PEAK

N-PEAK

N-PEAK

TWO-MODE

FIGURE 20

~ C

~ C

~ C

~ C

~ C

OMFOR

OMFOR

OMFOR

OMFOR

OMFORT

T

T

T

T

Z

Z

Z

Z

Z

O

O

O

O

ONE

NE

NE

NE

NE

~

~

~

~

~

Hi

Hi

Hi

Hi

High

gh

gh

gh

gh

Lo

Lo

Lo

Lo

Low

w

w

w

w

CHARGING

CHARGING

CHARGING

CHARGING

CHARGING

O

O

O

O

OVERRIDE

VERRIDE

VERRIDE

VERRIDE

VERRIDE

SENSOR

SENSOR

SENSOR

SENSOR

SENSOR

PEAK

PEAK

PEAK

PEAK

PEAK

O

O

O

O

ON-PEAK

N-PEAK

N-PEAK

N-PEAK

N-PEAK

OFF-PEAK

OFF-PEAK

OFF-PEAK

OFF-PEAK

OFF-PEAK

CANCEL

CANCEL

CANCEL

CANCEL

CANCEL

--O

--O

--O

--O

--O

VERRIDE

VERRIDE

VERRIDE

VERRIDE

VERRIDE

--

--

--

--

--

VARIABLE CHARGE

FIGURE 22

MULTI-MODE

FIGURE 21

O

O

O

O

O N-PEAK

N-PEAK

N-PEAK

N-PEAK

N-PEAK

CHARGING

CHARGING

CHARGING

CHARGING

CHARGING

~ C

~ C

~ C

~ C

~ C

OMFOR

OMFOR

OMFOR

OMFOR

OMFORT

T

T

T

T

Z

Z

Z

Z

Z

O

O

O

O

ONE

NE

NE

NE

NE

~

~

~

~

~

85

85

85

85

85

55

55

55

55

55

OFF-PEAK

OFF-PEAK

OFF-PEAK

OFF-PEAK

OFF-PEAK

Advertising