STEP CV Knobs 1-8

These adjust the CV level for each step.

DESTINATION

The output CV of the sequencer can be routed to VCO1 pitch, VCO2 pitch and VCF
cutoff. The level can be changed using the appropriate control.

You must tune the VCO1 and VCO2 mod level pots by ear so that both VCOs are
playing in unison. However, by adjusting them differently, you can make them seem to
play separate melodies, or in combination with other settings, create new and
interesting sounds.

Set lowish filter CUTOFF and VCF EG MOD settings, and full VCF Sequencer mod
settings and create great filter dynamics!

USING THE SEQUENCER AS AN AUDIO OSCILLATOR

Set SEQ SYNC to VCO2. This is so the sequencer will be clocked at audio frequencies.

On the mixer move the toggle switch to SEQ to route the output of the sequencer to the
mixer. This means you will hear the sequencer’s output.

The audio out is quite a harsh metal sound. Turn the sequencer step controls to change
the harmonics.