Ir speed dome operating manual, Auto scan, Scan no – COP-USA CD59NV-IRWP User Manual

Page 41

Advertising
background image

IR Speed Dome Operating Manual

40

 
AUTO SCAN 

 

       

The dome supports 8 groups of auto scan. Please check 

the following steps to set up a scan.

 

 

1)

SCAN NO.:

 Move the cursor here and press IRIS OPEN to enter the 

setup of SCAN Number. Move the joystick to select a preset number 
(1‐8) and press IRIS OPEN to confirm. 

 

2)

TITLE:

Move  the  cursor  here  and  press  IRIS  OPEN  to  enter  the 

setup  of  SCAN  Title.  Check  the  detailed  above  in  DOME  TITLE 
settings. 

 

3)

<LEFT LIMIT>:

Move  the  cursor  here  and  press  IRIS  OPEN  to 

enter. Move the dome to a defined position as left limit and press 
IRIS OPEN to save this left boundary. 

 

4)

<RIGHT LIMIT>:

Move  the  cursor  here  and  press  IRIS OPEN to 

enter. Move the dome to a defined position as right limit and press 
IRIS OPEN to save this right boundary. 

 

5)

START:

Move  the  cursor  here  and  press  IRIS  OPEN  to  start  the 

current scan. 

 

6)

SCAN SPEED:

Move the cursor here and press IRIS OPEN to set up 

the scan speed ranging 1‐30. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

MAIN MENU

LANGUAGE :ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
<CAMERA>
<MOTION>
RESTART
FACTORY DEFUALTS

HELP
EXIT

MOTION

<PRESET>
<SCAN>
<SEQUENCE>
<PATTERN>
<ZONES>
<TIMING ACTION>
<MOTION DETECT>
<AUTO TRACKING>

BACK EXIT

SCAN

SCAN NO. :1
TITLE :SCAN 1
START
<LEFT LIMIT>
<RIGHT LIMIT>
SCAN SPEED :20

BACK EXIT