Ir speed dome operating manual, Auto cruise(sequence) – COP-USA CD59NV-IRWP User Manual

Page 42

Advertising
background image

IR Speed Dome Operating Manual

41

 
AUTO CRUISE(SEQUENCE) 

 

 

       

The  dome  supports  8  groups  of  auto  cruise  and  each 

cruise  supports  32  presets.  .  Please  check  the  following 
steps to set up cruise.

 

 
1)

SEQ NO.:

Move  the  cursor  here  and  press  IRIS  OPEN  to  enter 

the  setup  of  Sequence  Number.  Move  the  joystick  to  select  a 
preset number (1‐8) and press IRIS OPEN to confirm. 

 
2)

TITLE:

Move the cursor here and press IRIS OPEN to enter the 

setup of Sequence Title. Check the detailed above in DOME TITLE 
Settings. 

 
3)

<SEQUENCE SET>:

 Move the cursor here and press IRIS OPEN         

to enter. Move the cursor to EDIT and press IRIS OPEN enter   
edit mode of sequence. Move the joystick left and right to   
select each item. 
 

a) When the < > is on the item NO., move joystick up or down 

to  select  the  Serial  NO.  of  the  preset  in  a  sequence.  There 
are up to 32 presets in each sequence. 

b) When the < > is on the item PRESET, move the joystick up or 

down to select the preset NO. that the user wants to add in 
the sequence. 

c) When  the  <  >  is  on  the  INTERVAL,  move  the  joystick  up  or 

down to select the interval time between each preset. 

d) When  the  <  >  is  on  the  last  item,  move  the  joystick  up  or 

down  to  select  edition  mode  as  “INS  (insert)”,  “ok”  and 
“delete”. 

 

 

Press IRIS OPEN when selecting INS to insert the settings into 

 

the position of current Serial No. 

 

Press IRIS OPEN when selecting OK to override the settings of 
Current Serial No. 
Press IRIS OPEN when selecting delete to delete the settings               
of the Current Serial No. 
Press IRIS OPEN to save all the setting and press IRIS CLOSE     
                                                          to exit.   

4) 

DELETE/START:

Move the cursor here and press IRIS OPEN to     

delete/start the current sequence. 

MAIN MENU

LANGUAGE :ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
<CAMERA>
<MOTION>
RESTART
FACTORY DEFAULTS
HELP
EXIT

MOTION

<PRESET>
<SCAN>
<SEQUENCE>
<PATTERN>
<ZONES>
<TIMING ACTION>
<MOTION DETECT>
<AUTO TRACKING>

BACK EXIT

SEQUENCE

SEQ NO. :1
TITLE :SEQ 1
START
<SEQUENCE SET>
DELETE

BACK EXIT

SEQUENCE

NO. PESET INTERVAL
>> 01 002 03
02 001 03
03 - - - - -
04 - - - - -
05 - - - - -
06 - - - - -
EDIT 01 003 03 INS

BACK EXIT

Advertising