Operation Manual for Intelligent Speed Dome Camera

13

maximum. Following table shows states of coding switches of protocols selected by the

dome camera

Protocol Settings Baud rate

Protocols

DIP-1 DIP-2 DIP-3 DIP-4 DIP-5 DIP-6

B01

ON

OFF

OFF

OFF

OFF

ON

Santachi

OFF ON OFF OFF OFF ON

PELCO-P/D

ON

ON

OFF

OFF

OFF

OFF

PELCO-MK

OFF OFF ON OFF OFF OFF

PANASONIC

ON

OFF

ON

OFF

OFF

ON

Longcomity

OFF ON ON OFF OFF ON

HUNDA600

ON

ON

ON

OFF

OFF

ON

LILIN

OFF OFF OFF ON OFF ON

VICON

ON

OFF

OFF

ON

ON

OFF

MOLYNX

OFF ON OFF ON OFF ON

KALATEL

ON

ON

OFF

ON

ON

OFF

VCL

OFF OFF ON ON OFF ON

SAMSUNG

ON

OFF

ON

ON

OFF

ON

ALEC

OFF ON ON ON OFF ON

Ultrak

ON

ON

ON

ON

OFF

ON

Table 2

Some protocols and the states of the coding switches of normal baud rate of these

protocols are shown as follows:

4. Setup of the Baud Rate of Communication. As shown in Figure 2, SW2 is used to set

the protocol of communication and the baud rate used by the dome camera. DIP-6 and

DIP-5 of SW2 are used to select the baud rate of communication and 4 different baud

rates can be selected in maximum. If the controller adopts non-standard baud rate, you

can adjust it to be identical with that of the controller as per the following table.

Setup of Baud Rate

Baud Rate of Communication

DIP-1

DIP-2

DIP-3

DIP-4

DIP-5 DIP-6

2400bps

OFF

OFF

4800bps

ON

OFF

Advertising