Operation Manual for Intelligent Speed Dome Camera

22

Figure 22

In such circumstances the factory recommends the usage of DR-HB16 RS485 distributor.

The distributor can change the star configuration connection to the mode of connection
stipulated in the RS485 standards. The new connection achieves reliable data
transmission (refer to Figure 23).

120

120

120

1#

2#

16#

. .

.

.

MC2080

A+

B-

Figure 23

Appendix

:

Wire Diameter and Transmission Distance Comparison Chart

Wire diameter (mm)

Transmission

Distance

feet(m)

Power [VA]

0.8000 1.000 1.250 2.000

10

28386 451137

716218

1811 551

20

14142 22568

358109

905275

30

94 28 15045

23872

603183

40

70 21 112 34 17954

452137

50

56 17 90

27 14343

362110