Regional settings, Telephone settings – ClearOne comm ClearOne RAV 900 User Manual

Page 19

Advertising
background image

RAV-Ware — Configuring System Settings

RAV-Ware — Configuring System Settings

Regional Settings

In the Regional Settings window, you can configure the date and time to ensure an accurate
time stamp on log files.

To open Regional Settings

Click the

Regional Settings

icon in the Configuration screen.

To set date and time

1. Select

Use Local Time

if you want to use

the time on your local computer.

– Or –

Clear the

Use Local Time

checkbox and

enter the

IP address

for the time server.

2. Select

Use Daylight Savings

if your region

observes daylight savings time.

3. Select your

Time Zone

and click

OK.

4. Click Yes to confirm changes.

Telephone Settings

In the Telephone Settings window you can set telephone preferences such as auto-answer,
auto-disconnect, ringer melody and program the local number. You can also adjust the telco
level control, country setting and the flash settings.

To open Telephone Settings

Click the

Telephone Settings

icon in the Configuration screen.

Figure 3.13. Date/Time settings

33

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

To change the User Name and Password

1. In the Networking tab, click

User/Password

.

2. Specify the

User name

. (Default is clearone.)

3. Type the

Password

. (Default is rav.)

4. Retype the password to confirm.

5. Click

OK

to save changes and close the window.

Note: This option is only available when you are
connected to a RAV unit.

To configure the Camera port

1. In the Serial tab, set the

Baud Rate

to match the

baud rate indicated in the camera specifications.

2. Select

Flow Control

to enable hardware flow

control.

3. Click

OK

to save settings and close the window.

To configure the Control port

1. Set the Control Port

Baud Rate

to match the baud

rate of the PC COM port or the control device.

2. Select

Flow Control

to enable hardware flow

control. (Flow Control is selected as default.)

3. Click

OK

to save settings and close the window.

Note: Flow Control is the regulation of information between two devices that are connected to
one another. ClearOne recommends enabling Flow Control on the RAV system.

Attention: If you are connected to the RAV unit through the serial port, you will need to reboot
the unit before the baud rate and flow control changes take place. If you are connected to the
RAV unit through the USB port, changes are made instantly.

To change RF frequency channel

1. In the Frequency tab, select a frequency.

2. Click

OK

to save settings and close the window

Note: The channel frequency allows the mixer to
communicate with the controller. The frequency used
by RAV-Ware must match the frequency used by the
controller. See page 58 to set the controller
frequency.

Attention: If you are using the European or South
African version of RAV Frequency 1 and Frequency
8 are the same frequency.

Figure 3.11. Serial settings

32

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Figure 3.10. User name/Password

Figure 3.12. Frequency settings

!

!