ClearOne comm ClearOne RAV 900 User Manual

Page 45

Advertising
background image

Appendix— Serial Commands

85

AEC - Acoustic Echo Canceller enable/ disable

This command selects/reports the setting of Acoustic Echo Canceller.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group And Channels

Group

Group

1

3 (M)

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle(Null to query in text)

BINARY FORM DETAILS

COMMAND ID:

27

NUMBER OF ARGUMENTS:

1

ARGUMENT FORM:

<Channel><Group><Value>

TEXT FORM DETAILS

COMMAND FORM:

DEVICE AEC <Channel> [Value]

AECREF - Acoustic Echo Cancellation Reference

This command enables/disables or reports the current status of the AEC reference.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Value

Unsigned Integer

4

1 - 3
(Null to query in text)

BINARY FORM DETAILS

COMMAND ID:

68

NUMBER OF ARGUMENTS:

1

ARGUMENT FORM:

<Value>

TEXT FORM DETAILS

COMMAND FORM:

DEVICE AECREF [Value]

AGC - Automatic Gain Control

This command selects/reports the setting of automatic gain control.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group And Channels

Group

Group

1

3 (M)

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

BINARY FORM DETAILS
COMMAND ID:

1

NUMBER OF ARGUMENTS:

1

ARGUMENT FORM:

<Channel><Group><Value>

TEXT FORM DETAILS
COMMAND FORM:

DEVICE AGC <Channel> <Group> [Value]

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Appendix — Serial Commands

84

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

ACONN - Audible Connect / Disconnect Indication

This command selects/reports the status of the audible connect/disconnect indication.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group and Channels

Group

Group

1

17 (R)

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

BINARY FORM DETAILS

COMMAND ID:

96

NUMBER OF ARGUMENTS:

1

ARGUMENT FORM:

<Channel><Group><Value>

TEXT FORM DETAILS

COMMAND FORM:

DEVICE ACONN <Channel> [Value]

AD - Auto Disconnect Enable/ Disable

This command selects/reports the setting of auto disconnect.

ARGUMENT DETAILS

Name

Type

Size

Values

Units

Channel

Channel

1

See Group and Channels

Group

Group

1

17 (R)

Value

Unsigned Integer

2

0 = Off
1 = Loop Drop
2 = Call Progress
3 = Loop Drop + Call Progress
(Null to query in text)

BINARY FORM DETAILS

COMMAND ID:

29

NUMBER OF ARGUMENTS:

1

ARGUMENT FORM:

<Channel><Group><Value>

TEXT FORM DETAILS

COMMAND FORM:

DEVICE AD <Channel> [Value]

Advertising
This manual is related to the following products: