# 3 Weigh-in / Weigh-out

This program uses the ID memory for weigh-in / weigh-out transactions. An ID

record is created using the Weigh-in function. The Weigh-out function recalls the

ID, calculates Gross/Tare/Net of the transaction, prints the transaction, and adds

the net weight to the ID’s totals register. The ID data is saved for further weigh-

in/weigh-out transactions, or weigh-out only transactions. A sequential

transaction number is maintained for printing purposes.

Weigh-In

Press the

F1

key. The display prompts "id". Enter up to 8 digits for the weigh-in

ID and then press the ENTER key. The scale weight is stored in the ID's tare

register and print page 3 is sent to the printer. If the ID has been weighed in but

not weighed-out then "Err 20" is displayed. Press the CLEAR key to exit without

changing the ID data, press the ENTER key to enter the new ID data.

Weigh-Out

Press the

F2

key. The display prompts "id". Enter up to 8 digits for the weigh-out

ID and then press the ENTER key. The indicator recalls the ID from memory,

calculates the gross, tare and net weights, totals the net weight and sends the

weigh-out data (page 2) to the printer. If an ID is entered that is not found in

memory the displays "Err 21". Press the CLEAR key to exit the weigh-out

function.
The print formats label “(IN) GROSS” for weigh-in gross transactions, “(IN)

TARE” for weigh-in tare transactions, and “MEM TARE” to designate Memory

tare for ID’s recalled 2 or more times.

Print ID’s, Display ID’s, Clear Totals, Erase ID’s

Entering ID 0 accesses the ID maintenance functions. Press the F1 (or F2) key,

press the numeric 0 key, and then press the ENTER key. The display prompts

"rePort". Press the UNITS (

) key or the PRINT (

) key to scroll through the ID

file maintenance menu.

REPORT:

Press the ENTER key when the display prompts "rePort". The

display then prompts "id". Enter an ID number to be printed or enter the numeric

0 to print all ID's and depress the enter key and report will be printed on port 1.

DISPLAY ID’s:

Press the ENTER key when the display prompts “diSPLA”. The

display then prompts “id”. Enter an ID number to display the data in its registers,

or enter 0 and then the ENTER key to scan ID memory.

CLEAR TOTALS:

Press the ENTER key when "CLEAr" is displayed. The

display prompts "id". Enter an ID number to clear or enter the numeric 0 to clear

all ID totals and depress the ENTER key.

ERASE ID'S:

Press the ENTER key when the display prompts "ErASE". The

display then prompts "id". Enter an ID to be erased or enter the numeric 0 to

erase all ID's and depress the ENTER key.