5 axle weigh – long scale, unattended – Industrial Data Systems IDS 430 User Manual

Page 23

Advertising
background image

IDS 430/433 Users Manual Version 1.0

- 23 -

# 5 Axle Weigh – Long Scale, Unattended

Automatically weigh multiple axles (or containers), print each axle weight, and

print axle (or containers) total.

Installation

Connect the Red light / Green light relays.

Green light =

TTL out 1

TB4 pin 1

Red light =

TTL out 2

TB4 pin 2

Ground =

GND

TB4 - Pin 4

+ 5 volts DC +5v TB3 - Pin 1

Setup Parameters

Configure the following parameters:

Parameter 43

Trip level weight. Determines when an axle is on the scale.

Parameter 74, 1

Red light turn delay timer. This provides a delay time before

the Red light output is turned on.

Parameter 74, 2

Green light turn delay timer. The amount of delay time

before the Green light is turned on.

Parameter 74, 3 Finish timers. Amount of time to wait before automatically

activating the finish function.

Operators Functions

The unit is capable of operating unattended, with no operator intervention. The indicator

determines when an axle is on the scale by the increase of weight on the scale.

A finish timer (parameter 74-3) determines when to complete a weigh cycle (print total

and wait for empty scale).

Press the F1 key to manually finish a weigh cycle before finish timer has timed out.

Press the F2 key to abort the weigh cycle.

Advertising