Industrial Data Systems IDS DT200 User Manual

Page 34

Advertising
background image

32

6.4 25 PIN 'D' CONNECTOR WIRING LIST

PIN #

SIGNAL NAME

1

CHASSIS GND

2

#1 RS232 TXD

3

#1 RS232 RXD

4

#1 RS232 RTS

5

#1 RS232 CTS

6

+5 R

7

GND

8

#1 CUR LOOP IN +

9

#2 RS232 RXD

10

#2 RS232 TXD

11

#2 RS485-

12

#2 RS485 +

13

GND

14

15

#1 PULSE INPUT

16

TTL INPUT

17

TTL INPUT

18

#2 CUR LOOP IN +

(#2 RS422 IN +)

19

#2 CUR LOOP IN -

20

+5 R

21

#2 RS422 IN -

22

#1 CUR LOOP IN -

23

+5 V

24

#2 CUR LOOP OUT

25

#1 TTL RTS

NOTES: When using RS232 INPUT, set DT210 jumper W2 on and W3 off. When using

current loop set jumper W3 on and W2 off.

When not using handshake jumper CTS to RTS (pin 5 to 4).

When using the Star Micronics DP8340, use pin 20 on the

DP8340 for "CTS" signal.