Industrial Data Systems IDS DT200 User Manual

Page 9

Advertising
background image

7

3.1.3 CONFIGURE SCALE

Activate the CONFIGURE menu and press the ENTER key when the

DT210 displays 'CONFIG SCALE'.

The DT210 prompts: "CONDEC/WS700T" (or current meter that is selected.)

The meter select menu is:

"NCI5790"

"ANALOGIC AN5316"

"CONDEC / WS700T"

"AND / GENERAL"

"CARDINAL 738"

"TOLEDO 8142"

"WI 110"

"DR 10K"

"SSD800"

Press the CONTINUE key to scan the meter list. Press the ENTER key to select a meter type.

The DT210 prompts: "UNITS = XXXX"

where XXXX = the scale units being sent by the scale indicator.

Note: if the scale input units do not match the units configured the DT210 display will show the

error message: -U-

The scale units menu selections are:

"UNITS = UNDEF." - units not set.

"UNITS = LB" - sets units to lbs.

"UNITS = KG" - sets units to kgs.

"UNITS = TON" - sets units to tons.

"UNITS = TNE" - sets units to metric tons.

Press the CONTINUE key to scan the scale units selections . Press the ENTER key to complete

the scale units selection.

The DT210 prompts: "COUNT BY XX"

where XX = count-by graduations of the weight indicator. Press the ENTER key to use the

displayed count-by or enter a new count-by number. The valid count-by's are:

.01 .02 .05 0.1 0.2 0.5 1 2 5 10 20 50

If the DT210 internal motion detect option is installed -

Advertising