GF-122 AERCO XPC GATEWAY

181

Modbus-To-LonWorks Protocol Mapping 1 BMS II, 4 MLX Boilers (Continued)

Equipment

Point Name

Name

Modbus Data

Addr/Unit Addr

Read

Only Enabled

SNVT

#

SNVT NAME

SNVT

Element

#

Direction

Prio Auth Ack

Mlx Addr 3

01-Act Mod Lev

boilerstate_3

41009/3

181

nvoMlxState3

incremental
count (9)

0

Output (non-
polled)

02-Target Setpoint

effectsetpt_3

41019/3

182

nvoMlxSetpt3

incremental
count (9)

0

Output (non-
polled)

03-Req Outlet
Temp

setpt_3

41005/3

183

nviMlxSetptRq3

incremental
count (9)

0

Input (non-
polling)

04-Net Direct Drive

boilercmd_3

40002/3

184

nviMlxCmd3

incremental
count (9)

0

Input (non-
polling)

05-Mod Lev In

boilerload_3

41201/3

185

nvoMlxLoad3

incremental
count (9)

0

Output (non-
polled)

06-Flow Sens
Temp

localsuptemp_3

41003/3

186

nvoMlxSupTmp3

incremental
count (9)

0

Output (non-
polled)

07-Display Code

dispcode_3

30001/3

188

nvoMlxDispCode3

incremental
count (9)

0

Output (non-
polled)

11-Error Code

errcode_3

40001/3

189

nvoMlxErrCode3

51

0

Output (non-
polled)

08-Unit Status

unitstat_3

30002/3

190

nvoMlxStat3

incremental
count (9)

0

Output (non-
polled)

09-Ret Flow Temp

returntemp_3

41004/3

187

nvoMlxRetTmp3

incremental
count (9)

0

Output (non-
polled)

Mlx Addr 4

01-Act Mod Lev

boilerstate_4

41009/4

191

nvoMlxState4

incremental
count (9)

0

Output (non-
polled)

02-Target Setpoint

effectsetpt_4

41019/4

192

nvoMlxSetpt4

incremental
count (9)

0

Output (non-
polled)

03-Req Outlet
Temp

setpt_4

41005/4

193

nviMlxSetptRq4

incremental
count (9)

0

Input (non-
polling)

04-Net Direct Drive

boilercmd_4

40002/4

194

nviMlxCmd4

incremental
count (9)

0

Input (non-
polling)

05-Mod Lev In

boilerload_4

41201/4

195

nvoMlxLoad4

incremental
count (9)

0

Output (non-
polled)

06-Flow Sens
Temp

localsuptemp_4

41003/4

196

nvoMlxSupTmp4

incremental
count (9)

0

Output (non-
polled)

07-Display Code

dispcode_4

30001/4

198

nvoMlxDispCode4

incremental
count (9)

0

Output (non-
polled)

11-Error Code

errcode_4

40001/4

199

nvoMlxErrCode4

51

0

Output (non-
polled)

08-Unit Status

unitstat_4

30002/4

200

nvoMlxStat4

incremental
count (9)

0

Output (non-
polled)

09-Ret Flow Temp

returntemp_4

41004/4

197

nvoMlxRetTmp4

incremental
count (9)

0

Output (non-
polled)