Security

7-16

Enabling Security and Traps

Figure 7-6. Channel X Module Security Window

3.

Use the Set Security For field or the mouse to select the module or modules
for which you wish to configure security (note that the settings in the Set
Security For
field will change automatically as you click to select or de-select
modules).

4.

In the Security Mode field, click mouse button 1 on the appropriate selection
to apply Full or Continuous lock status to all ports on the selected modules,
or to Unlock all ports on the modules. (Note that if your EMM-E6 does not
support the newest security enhancements, the Continuous selection will be
unavailable.)

5.

Click on the appropriate selection in the Send Trap field to Enable or Disable
traps for the selected module(s).

6.

Click on

to save your changes; each module’s current status will

be displayed in the scroll list. Click on

to exit the window.