3 inst alla tion, P.11 – Camco 32 dB User Manual

Page 12

Advertising
background image

MODEL:

OUTPUT PWR PER CH/IMP:

MADE IN GERMANY

SER. NO.:

VORTEX-200 V

230 V ~ 50/60 Hz 12 A 1700 W

3200 W / 4 Ohm

xxxxxxx

MODEL:

OUTPUT PWR PER CH/IMP:

MADE IN GERMANY

SER. NO.:

VORTEX-2.6

230 V ~ 50/60 Hz 7,2 A 1005 W

1500 W / 1,8 Ohm

xxxxxxx

MODEL:

OUTPUT PWR PER CH/IMP:

MADE IN GERMANY

SER. NO.:

VORTEX-4

230 V ~ 50/60 Hz 10 A 1450 W

2000 W / 2 Ohm

xxxxxxx

MODEL:

OUTPUT PWR PER CH/IMP:

MADE IN GERMANY

SER. NO.:

VORTEX-6

230 V ~ 50/60 Hz 12 A 1800 W

3000 W / 2 Ohm

xxxxxxx

3 INST

ALLA

TION

USER MANUAL
VORTEX 6, 4, 2.6 and 200V

P.11

3.1 Mains supply

When mounting or connecting the amp always disconnect it from mains.

Only connect the VORTEX amplifi er to an appropriate AC circuit and outlet,

according to the requirements indicated in the second line on the rating

plate.

Exemplary rating plates for a mains supply of 230 V AC 50/60 Hz.

Power Supply Data:

Voltage

Mains Frequency

Current

Power Consumption

VORTEX-200V 120 V

50/60 Hz

24 A

1700 W

VORTEX-200V 220 V

60 Hz

12 A

1700 W

VORTEX-200V 230 V

50/60 Hz

12 A

1700 W

VORTEX-6

100 V

50/60 Hz

28 A

1800 W

VORTEX-6

120 V

50/60 Hz

24 A

1800 W

VORTEX-6

220 V

60 Hz

12 A

1800 W

VORTEX-6

230 V

50/60 Hz

12 A

1800 W

VORTEX-4

100 V

50/60 Hz

24 A

1450 W

VORTEX-4

120 V

50/60 Hz

20 A

1450 W

VORTEX-4

220 V

60 Hz

10 A

1450 W

VORTEX-4

230 V

50/60 Hz

10 A

1450 W

VORTEX-2.6

120 V

50/60 Hz

14,4 A

1005 W

VORTEX-2.6

220 V

60 Hz

7,2 A

1005 W

VORTEX-2.6

230 V

50/60 Hz

7,2 A

1005 W

NOTE: Even under normal conditions the mains current can reach levels up

to 60 A (230 V), 120 A (120 V) and 140 A (100 V), respectively; this could

cause lamps to fl icker if connected to the same mains as the amp. The im-

pedance of the AC circuit should be less than 0,157 Ohms to avoid fl icker

according to EN61000-3-11 “Electromagnetic compatibility – Part 3-11:

Limits – Limitation of voltage changes, voltage fl uctuations and fl icker in

the public low-voltage supply systems – Equipment with rated current
75 A and subject to conditional connection”.
If in any doubt, consult your local power provider. Never attempt to mea-

sure this impedance level with your ohmmeter. This may damage your me-

ter and expose you to the risk of electric shock!

3.2 On/Off Switch

NOTE: This switch does NOT disconnect the amplifi er from mains.

The switch initiates start-up by activating the current limiting function. As soon

as the power amplifi er is connected to the mains power supply, a voltage is

supplied to both the line-fi lter and the fused input of the controllable rectifi er.

Disconnecting the amplifi er from the main power supply can only be achieved

by physically separating the amplifi er from the mains by pulling the mains plug.

The mains plug therefore has to be freely accessible. Disconnect the mains plug

from the mains during a lightning storm or when the amplifi er remains unused

or un-supervised for a prolonged period of time. Alternatively, you can discon-

nect the amplifi er via an external all-pole disconnection from the mains.

If a power cut occurs while the amplifi er is switched on, it will restart auto-

matically once the power supply has been restored. All settings prior to the loss

of power will be maintained.

Advertising
This manual is related to the following products: