3 inst alla tion, P.14 – Camco 32 dB User Manual

Page 15

Advertising
background image

A (L)

B (R)

VORTEX

Z

≥ *Z

min

Z

≥ *Z

min

VORTEX

A

B

Z

res

≥ 0,5*Z

min

Input

Ground

Lift

Input Ground Lift in
position: grounded

LINK B

Input

Channel B

2

3

1

1

3

2

2

3

1

To

Channel B

To

Channel A

Input

Channel A

LINK A

3

1

2

3 INST

ALLA

TION

USER MANUAL
VORTEX 6, 4, 2.6 and 200V

P.14

3.8 Mode Selector

The switch on the rear panel changes the operating mode. Moving this switch

will shutdown the amplifi er and restart it in the new operating mode.

3.9 Wiring

3.9.1 E.U.I. and XLR Connection

XLR: Pin 1 = Ground (or lifted via 15

Ω resistor)

Pin 2 = Hot (inphase)

Pin 3 = Cold (out of phase)

Always use symmetrical (balanced) shielded cable to connect the amplifi er.

3.9.2 Stereo Operation

Two fully independent amplifi er channels (normal operating mode).

3.9.3 Parallel-Mono Operation

Parallel operation of the two channels together.

The output terminals of the two channels are confi gured in parallel using an

internal relay. The (single) load is connected either to the output of channel A

or to that of channel B (as if in stereo). While the total output of the amplifi er

remains the same and the output voltage level is also the same as in stereo op-

eration, the minimum impedance that can be connected is reduced by half due

to the fact that current capability is doubled. Only channel A-Input is active. The

channel B-Input is inactive – turn the volume on channel B down to zero. This

Advertising